Building Services Commissioning Ltd
Get In Touch Menu

Commissioning Engineers - Lincolnshire

Welcome to Building Services Commissioning Ltd, specialist commissioning engineers, offering a comprehensive range of services in the commissioning of heating, cooling and ventilation systems for industrial and commercial customers throughout Lincolnshire and the UK. 

The company and staff are all members of the Commissioning Specialists Association.

Established in 1995, we have a wealth of knowledge and experience in the building commissioning industry. We ensure that all recently installed heating, cooling and ventilation systems are monitored and thoroughly tested, before commissioning them for use, providing relevant certification to the necessary parties.

Our Commissioning Services Include:

  • Heating and cooling systems
  • Water treatment
  • Commissioning management
  • BREEAM seasonal commissioning
  • Sound level testing
  • Ventilation systems
  • Environmental testing
  • Operating theatre validation

Verification / Validation Services

Our verification services are suitable for all types of ventilation, heating, and cooling systems and are designed to establish their current performance.

Following testing, we provide comprehensive reports detailing our findings, evaluating system performance and comparing measured results against the original design criteria and client-specified targets. All verification works are undertaken in accordance with the relevant requirements of HTM 03-01.

Why Building Services Commissioning Ltd?

Our mission is simple. To provide an efficient team of commissioning engineers who pride themselves on carrying out all work to the highest of standards. Our commitment to achieving high levels of customer service has enabled us to undertake a wide variety of commissioning contracts for a large number of clients, across a variety of sectors, some of which include:

  • Commercial and industrial buildings
  • Hotel and leisure facilities
  • The Ministry of Defence
  • Universities and schools
  • Hospitals
  • Prisons

Frequently Asked Questions

  • What does a commissioning engineer actually do?

    A commissioning engineer takes a newly installed heating, cooling or ventilation system from a static state and brings it into full working order. That means setting the system to work, measuring air and water flow rates, balancing the system so that each part of it delivers the intended performance, and recording the results against the original design. The work is carried out after installation but before handover, and provides the evidence that a system does what it was designed to do.

  • What is the difference between commissioning, verification and validation?

    Commissioning is carried out on a new installation to bring it into working order and prove it meets the design. Verification is undertaken on an existing system to establish its current performance and compare it against the original design criteria. Validation is the term generally used for specialist environments such as operating theatres, isolation rooms and laboratories, where systems must be proven against defined standards on a recurring basis. We provide all three.

  • Why does a system need commissioning if it has been installed correctly?

    Installation and performance are not the same thing. A correctly installed system will still deliver too much air or water to some parts of a building and too little to others until it is balanced, because flow naturally follows the path of least resistance. Commissioning identifies and corrects those imbalances, so that every terminal, room and circuit receives what the design intended. It also demonstrates compliance, as commissioning is a requirement of the Building Regulations for most fixed building services.

  • What happens if a system fails to meet its design performance?

    We report exactly what we have measured and, wherever possible, identify the cause - an undersized fan or pump, a blocked or leaking duct, a valve set incorrectly, or a design assumption that does not hold on site. Where the shortfall can be resolved by adjustment we will do so and re-test. Where it requires remedial work by the installing contractor, we record the position clearly so that responsibility is evident and the system can be re-tested once corrected.

  • Do you carry out testing on existing systems, or only new installations?

    Both. Alongside commissioning of new installations, we regularly test and verify existing systems to establish current performance, support a change of use, investigate comfort or air quality complaints, or meet recurring compliance obligations such as annual healthcare ventilation verification. Following testing we provide a report detailing our findings and comparing measured results against the design criteria and any client-specified targets.

Contact Us
View Map Close Map